Product Code : 2342122
Price And Quantity
Product Specifications
  • Weight
  • 500 Kilograms (kg)
  • Temperature
  • Ambient to +180 Celsius (oC)
  • Voltage
  • 415 Volt (v)
  • Application
  • To test electronic components and modules as per MILL, JSS, ASTM, IEC, ASTM standards etc.
Product Description

Leveraging on our knowledge, we manufacture and supply a wide range of High Temperature Test Chambers. Available in different standard specifications, these chambers are widely used in research institutions, hospitals and laboratories. Manufactured in compliance with set industry standards, these test chambers are extensively demanded for conducting stringent tests on various electronic substances and components. Before the final dispatch, we make sure to check the quality of these High Temperature Test Chambers on parameters of rigidity, strength and robustness.

Features:

  • Long service life
  • Easy installation
  • Robust construction
 

Application

To test electronics components and modules as per MIL, JSS, IEC, ASTM, standards etc

Model

Cometair-WITC

Volume

8 cubic meters

Workspace dimensions

2Mtrx2Mtrx2Mtrs(WxDxH)

Connected load

15kw

Temperature range

50 deg C to +100 deg C

Temperature tolerance

+ deg .C thru' out the range

Instrumentation

Eurotherm temperature programmer controller capable of performing 20
programs with unlimited segment and repeats. PC based RS232 serial
communication is provided. Additional iTools software to interact with PC.
PLC package for function and faults.
Mimic panel along with test lam module for status of components

Insulation

Polyurethane foam (PUF) for both body and door

Gasket

Double gasket, made of silicon rubber is used to withstand the temperature variation thru' out the range.

Thermal breaker strips

Stainless steel 304 strips backed up by tracer tape heaters.

Air circulation

By high volume air circulation blowers connected to external extended SS shaft motors.

Heating

By inconel clad air heater situated such that no direct radiation falls on test specimen.

Power supply

415V, 3-Phase, 50Hz with neutral

Safety features

Time delay in starting of compressors
Pressure switches in refrigeration systems
High temp. safety cut out in case of temperature overshoot
Adjustable product safety temp. controller to safeguard components